File: FIXTAB.PA of Tape: Sources/Focal/s9
(Source file text) 

/SYSTEM INSTRUCTIONS (NOT LISTED)

/PERMANENT SYMBOLS FOR PAL8

/PDP8/E-SYMBOLS
BSW=7002
MQL=7421
MQA=7501
SWP=7521
CAM=7621
SKON=6000
SRQ=6003
GTF=6004
RTF=6005
SGT=6006
CAF=6007
CINT=6204
SINT=6254
CUF=6264
SUF=6274

/VARIOUS 8E OR NEW INSTRUCTIONS
KCF=6030
KIE=6035
TFL=6040
TSK=6045
RPE=6010
RIE=6013	/S/CL ERR. INT. (READER)
RCR=6015	/CLEAR READER/PUNCH ERROR
RSE=6017	/SKIP ERROR READER
PCE=6020
PIE=6023	/S/CL ERR. INT. (PUNCH)
PSK=6025	/SKIP ON READER OR PUNCH FLAG
PSE=6027	/SKIP ERROR PUNCH

/KE8-E (EAE)-SYMBOLS
SWAB=7431
SWBA=7447
SKB=7671
SCA=7441
SCL=7403
MUY=7405
DVI=7407
NMI=7411
SHL=7413
ASR=7415
LSR=7417
ASC=7403
SAM=7457
DAD=7443
DLD=7663
DST=7445
DPIC=7573
DCM=7575
DPSZ=7451

/DISPLAY PLOTTER CODES
DLXA=6060	/LOAD X REGISTER FROM AC
DLXB=6061	/LOAD X REGISTER FROM AC, CLEAR AC
DLXC=6062	/LOAD X REGISTER FROM AC AND INTENSIFY
DLXD=6063	/LOAD X REGISTER FROM AC, CLEAR AC, INTENSIFY
DSPA=6064	/PEN UP
DSPB=6065	/PEN DOWN
DINX=6066	/INCREMENT X AND INTENSIFY
DSC=6067	/DISPLAY CHARACTER FROM AC
DLYA=6070	/LOAD Y REGISTER FROM AC
DLYB=6071	/LOAD Y REGISTER FROM AC AND CLEAR AC
DLYC=6072	/LOAD Y REGISTER FROM AC AND INTENSIFY
DLYD=6073	/LOAD Y REGISTER FROM AC, CLEAR AC, INTENSIFY
DCHS=6074	/SCOPE CHANNEL
DCHP=6075	/PLOTTER CHANNEL
DINY=6076	/INCREMENT Y AND INTENSIFY
DCSI=6077	/CLEAR STATUS, INTERRUPT ENABLE REGS.
DIEN=6050	/LOAD INTERRUPT ENABLE REGS. FROM AC
DSPD=6051	/SKIP ON POINT DONE FLAG AND CLEAR FLAG
DSCD=6052	/SKIP ON CHARACTER DONE FLAG AND CLEAR FLAG
DSLP=6053	/SKIP ON FORTRAN FLAG AND CLEAR FLAG
DSDF=6054	/SKIP ON ANY FLAG
DRIS=6055	/READ INTERRUPT FLAGS INTO AC,CLEAR FLAGS
DSFF=6056	/SET FAST PLOTTING
DCFF=6057	/CLEAR FAST PLOTTING

/PROGRAMMABLE REAL TIME CLOCK DK8-EP

CLZE=6130	/CLEAR CLOCK ENABLE REGISTER PER AC
CLSK=6131	/SKIP ON CLOCK INTERRUPT
CLOE=6132	/SET CLOCK ENABLE REGISTER PER AC
CLAB=6133	/AC TO CLOCK BUFFER
CLEN=6134	/LOAD CLOCK ENABLE REGISTER
CLSA=6135	/CLOCK STATUS TO AC
CLBA=6136	/CLOCK BUFFER TO AC
CLCA=6137	/CLOCK COUNTER TO AC

/DIGITAL INTEGRATOR INSTRUCTIONS.

INCF=6146	/CLEAR FLAG
INSF=6141	/SKIP
INLHI=6142	/LOAD HI,INHIBIT COUNT
INLLO=6143	/LOAD LO,ENABLE COUNT
INRHI=6144	/READ HI,INHIBIT BUFFER LOAD
INRLO=6145	/READ LO,ENABLE BUFFER LOAD
INIE=6147	/SET/CLEAR INT. ENABLE (DATA 11)

/S/C  SHUNT DVM

SCEI=6150	/ENABLE INTERRUPTS
SCDI=6151	/DISABLE INTERRUPTS
SCSF=6152	/SKIP ON DONE FLAG
SCCF=6153	/CLEAR FLAGS
SCRL=6154	/READ LOW ORDER BCD
SCRH=6155	/READ HIGH ORDER BCD AND STATUS
SCST=6156	/START MEASUREMENT
SCSE=6157	/SKIP ON ERROR FLAG

/DAC INSTRUCTIONS

DAL1=6161	/LOAD DAC1
DAL2=6162	/LOAD DAC2
DAL3=6163	/LOAD DAC3
DASK=6164	/SKIP ON ANY DAC FLAG
DARS=6165	/READ STATUS
DALS=6166	/LOAD STATUS;CLEAR SELECTED FLAGS
DACL=6167	/LOCAL INIT

/MAGNET CODES

MARL=6170	/READ LOW ORDER BCD
MARH=6171	/READ HIGH ORDER BCD
MARM=6172	/READ MODE
MASD=6173	/SKIP ON DONE FLAG
MACL=6174	/CLEAR FLAG
MALM=6175	/LOAD MODE
MALH=6176	/LOAD HIGH ORDER
MALL=6177	/LOAD LOW ORDER

/FIRST EXTRA TERMINAL

KCF1=6300
KSF1=6301
KCC1=6302
KRS1=6304
KIE1=6305
KRB1=6306

TFL1=6310
TSF1=6311
TCF1=6312
TPC1=6314
TSK1=6315
TLS1=6316

/SYSTEM INDUSTRIES MOD43 DISK

DSDD=6501	/SKIP ON DISK DONE
DLCR=6502	/LOAD CONTROL REGISTER
DRCR=6503	/READ CONTROL REGISTER
DCSR=6504	/CLEAR STATUS REGISTER
DRSR=6505	/READ STATUS REGISTER
DLSS=6506	/LOAD SEEK ADRESS REG. AND OVERLAP SEEK
DRSS=6507	/READ SEEK STATUS REGISTER
DSDE=6511	/SKIP ON DISK ERROR
DLSR=6512	/LOAD SECTOR ADRESS REGISTER
DSRR=6513	/READ SECTOR ADRESS REGISTER
DLTR=6514	/LOAD TRACK ADRESS REG. AND INITIATE READ
DLTW=6515	/LOAD TRACK ADRESS REG. AND INITIATE WRITE
DRTR=6516	/READ TRACK ADRESS REG.
DWCA=6517	/INITIATE WC AND CA SEQUENCE

/BUFFERED DIGITAL I/O #1

DBDI=6520
DBEI=6521
DBSK=6522
DBCI=6523
DBRI=6524
DBCO=6525
DBSO=6526
DBRO=6527

/A/D CONVERTER AD8-A

ADCL=6530	/CLEAR ALL
ADLM=6531	/LOAD MUX, CLEAR AC
ADST=6532	/CLEAR FLAGS AND START
ADRB=6533	/CLEAR FLAG AND READ
ADSK=6534	/SKIP IF DONE
ADSE=6535	/SKIP IF ERROR
ADLE=6536	/LOAD ENABLE, CLEAR AC
ADRS=6537	/READ STATUS,ENABLE,MUX

/BUFFERED DIGITAL I/O #2

DCDI=6540
DCEI=6541
DCSK=6542
DCCI=6543
DCRI=6544
DCCO=6545
DCSO=6546
DCRO=6547

/TIMER/COUNTER CODES
TCEI=6570	/SET OR CLEAR INTERRUPT
TCSD=6571	/SKIP ON DONE FLAG
TCSE=6572	/SKIP ON ERROR FLAG
TCCL=6573	/CLEAR ALL
TCME=6574	/SET TC MODE AND MEASURE
TCRB=6575	/READ BCD (TWICE)
TCSF=6576	/SET FUNCTION
TCRF=6577	/READ FUCTION
CTSI=6560	/SKIP ON ANY INTERRUPT
CTSA=6561	/CLOCK STATUS TO AC
CTCB=6562	/CLOCK COUNTER TO BUFFER
CTCT=6563	/RELEASE CT MODE
CTST=6564	/SET CT MODE
CTRB=6565	/READ BCD (CT MODE)
CTSF=6566	/SET FUNCTION
CTRF=6567	/READ FUNCTION


/TALLY LINE PRINTER WITH TTY: INTERFACE

LWT=6651
LCF=6652
LSF=6661
LLS=6666

FIXTAB